SPE関連規格
IEEE802.3、IEC61156、IEC63171規格内のシングル・ペア・ケーブルを用いた通信・給電規格を以下に記載する。
通信・給電規格:IEEE802.3(IEEE Standard for Ethernet 2018)
・IEEE802.3bw
Physical Layer Specifications and
Management Parameters for 100Mb/s Operation over a Single Balanced Twisted Pair Cable
・IEEE802.3bp
Physical Layer Specifications and Management Parameters for 1Gb/s Operation over a Single Twisted Pair Copper Cable.
・IEEE802.3bu
Physical Layer and Management Parameters for Power over Data Lines (PoDL) of Single Balanced Twisted
Pair Ethernet PoDL (Power over Data Line)
・IEEE802.3cg
Physical Layer Specifications and Management Parameters for 10 Mb/s Operation and Associated Power Delivery over a
Single Balanced Pair of Conductors 10BASE T1 (L) (10Mbps Single Pair Ethernet)
・IEEE P802.3ch
Physical Layer Specifications and Management Parameters for 2.5Gb/s, 5Gb/s, and 10Gb/s Automotive Electrical Ethernet
・IEEE P802.3da
10 Mb/s Single Pair Multi drop Segments Enhancement Task Force
・IEEE P802.3dd
Power over Data Lines of Single Pair Ethernet (Maintenance #17) Task Force.
・IEEE P802.3de
Time Synchronization for Point-to-Point Single Pair Ethernet Task Force.
・IEEE P802.3dg
100 Mb/s Long-Reach Single Pair Ethernet Task Force.
本ガイドラインに関連する及び参照するその他のIEEE802.3規格を以下に記載する。
- ・IEEE802.3af (Power over Ethernet)
- ・IEEE802.3at (Power over Ethernet)
- ・IEEE802.1ab (Local Link Discovery Protocol)
- ・IEEE802.1ah (Ethernet OAM)
ケーブル・コネクタ規格:IEC
・IEEE61156-11
Multicore and symmetrical pair/quad cables for digital communicationsPart 11: Symmetrical single pair cables
withtransmission characteristicsup to 600 MHz – Horizontal floor wiring – Sectional specification.
・IEEE61156-12
Multicore and symmetrical pair/quad cables for digital communications –Part 12: Symmetrical single pair cables with transmission characteristics up to 600 MHz –work area wiring – Sectional specification
・IEC 61156-13, (Draft)
Multicore and symmetrical pair/quad cables for digital communications –Part 13: Symmetrical single pair cables with transmission characteristics up to 20 MHz –horizontal floor wiring – Sectional specification
・IEC 61156-14, (Draft)
Multicore and symmetrical pair/quad cables for digital communications –Part 14: Symmetrical single pair cables with transmission characteristics up to 20 MHz – workarea wiring – Sectional specification
・IEC 63171-1
Detail specification for two-way, shielded or unshielded, free andfixed connectors – Mechanical mating information, pin assignment andadditional requirements for Type 1copper LC style
・IEC 63171-6
Detail specification for 2-way and 4-way (data/power),shielded, free and fixed connectors for power and datatransmission with frequencies up to 600MHz